15-00044
Revision 5
April 2008
The publication, translation or reproduction, either party or wholly, of this document are not allowed without our written consent. 31
6.1.2 Set down load interval Time=34H
PC to meter
0 1 2 3 4 5 6 7 8 9 10
LF 34 Sec*
1000
Sec*100 Sec*
10
sec 20 20 0F 0F CR
The interval time can be set from between 0 and 99
6.1.3 Set Threshold alarm value=35H
PC to meter
0 1 2 3 4 5 6 6 7 8 9
LF 35 X Y Z W T 20 0F 0F CR
6.1.4 Set Dose status = 37H
PC to meter
0 1 2 3 4 5 6 7 8 9 10
LF 37
D-30
E-31
2
0
20 20 20 20 0F 0F CR
6.1.5 Set meter serial no. = 38H
PC to meter
0 1 2 3 4 5 6 7 8 9 10
LF 38
D5 D4 D3 D2 D1 D0 0F 0F CR
6.1.6 Set Baud Rate = 31H
PC to meter
0 1 2 3 4 5 6 7 8 9 10
LF 31
code 2
0
20 20 20 20 0F 0F CR
Code:
30h=300 32h=9600
31h=4800 33h=19,200
Vedere la pagina 30